A surface mounted bathroom light: the same idea rated for directly above a bath, which is a different gasket and a different lens rather than a different sticker.
Bathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.
Specification
- Zone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it
- IP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower
- Dimensions: 300mm diameter by 60mm deep
- Light output: 1600 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.
- Colour temperature: chosen above
- Colour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup
- Dimming: mains dimmable, trailing edge
- Electrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling
- Fire rating: not applicable to a wall or surface mounted fitting
- Standards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked
- Weight: approximately 1.4 kilograms
- Guarantee: five years on the fitting and the LED module, two years on the driver
- Finish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years
- Mounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate
- Diffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade
- Sensor: none fitted
What arrives
- the fitting
- the gasketed base plate and gasket
- fixings for a joist and for plasterboard
- installation instructions
Installation
A registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.
Choosing between this and the alternatives
A single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.