{"title":"Downlight Trade Packs","description":"\u003cp\u003eTens, twenties and thirties from a single LED bin, so the colour temperature matches right across a ceiling. Reordering six months later without batch matching is how a corridor ends up with two shades of white.\u003c\/p\u003e","products":[{"product_id":"fire-rated-ip65-downlight-trade-pack-in-matt-white","title":"Fire Rated IP65 Downlight Trade Pack in Matt White","description":"\u003cp\u003eA trade pack of fire rated downlights: the plain one: 30, 60 and 90 minute fire rated, IP65, integral driver, and a price per fitting that makes sense at ten.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023133577598,"sku":"BBM-FRP-001-P10","price":1024.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023133610366,"sku":"BBM-FRP-001-P20","price":1974.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023133643134,"sku":"BBM-FRP-001-P30","price":2849.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_in_Matt_White.jpg?v=1789239729"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-tunable-colour-in-matt-white","title":"Fire Rated IP65 Downlight Trade Pack with Tunable Colour in Matt White","description":"\u003cp\u003eA trade pack of fire rated downlights: a switch on the back selects 2700K, 3000K or 4000K, so one box covers a whole house and the bathroom does not have to be a separate order.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023133872510,"sku":"BBM-FRP-004-P10","price":1274.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023133905278,"sku":"BBM-FRP-004-P20","price":2424.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023133938046,"sku":"BBM-FRP-004-P30","price":3499.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_Tunable_Colour_in_Matt_White.jpg?v=1789239739"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-dim-to-warm-in-matt-black","title":"Fire Rated IP65 Downlight Trade Pack with Dim to Warm in Matt Black","description":"\u003cp\u003eA trade pack of fire rated downlights: the colour temperature falls from 2700K to 1800K as it dims, which is what a halogen did and what people are actually asking for when they say they miss halogen.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023134265726,"sku":"BBM-FRP-008-P10","price":1374.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023134298494,"sku":"BBM-FRP-008-P20","price":2624.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023134331262,"sku":"BBM-FRP-008-P30","price":3799.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_Dim_to_Warm_in_Matt_Black.jpg?v=1789239735"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-cri-97-in-matt-white","title":"Fire Rated IP65 Downlight Trade Pack with CRI 97 in Matt White","description":"\u003cp\u003eA trade pack of fire rated downlights: CRI 97 with R9 above 90, which is a photographic specification and worth the money in a bathroom and a kitchen and nowhere else.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 95, measured, with R9 above 60. R9 is the deep red value and it is the one that decides whether skin looks like skin. Most bathroom fittings quote a CRI in the eighties and do not quote R9 at all, which is how you end up shaving by a light that makes you look ill\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023134364030,"sku":"BBM-FRP-009-P10","price":1174.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023134396798,"sku":"BBM-FRP-009-P20","price":2249.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023134429566,"sku":"BBM-FRP-009-P30","price":3224.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_CRI_97_in_Matt_White.jpg?v=1789239735"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-cri-97-in-brushed-chrome","title":"Fire Rated IP65 Downlight Trade Pack with CRI 97 in Brushed Chrome","description":"\u003cp\u003eA trade pack of fire rated downlights: CRI 97 with R9 above 90, which is a photographic specification and worth the money in a bathroom and a kitchen and nowhere else.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 95, measured, with R9 above 60. R9 is the deep red value and it is the one that decides whether skin looks like skin. Most bathroom fittings quote a CRI in the eighties and do not quote R9 at all, which is how you end up shaving by a light that makes you look ill\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023134462334,"sku":"BBM-FRP-010-P10","price":1274.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023134495102,"sku":"BBM-FRP-010-P20","price":2449.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023134527870,"sku":"BBM-FRP-010-P30","price":3549.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_CRI_97_in_Brushed_Chrome.jpg?v=1789239740"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-cri-97-in-matt-black","title":"Fire Rated IP65 Downlight Trade Pack with CRI 97 in Matt Black","description":"\u003cp\u003eA trade pack of fire rated downlights: CRI 97 with R9 above 90, which is a photographic specification and worth the money in a bathroom and a kitchen and nowhere else.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 95, measured, with R9 above 60. R9 is the deep red value and it is the one that decides whether skin looks like skin. Most bathroom fittings quote a CRI in the eighties and do not quote R9 at all, which is how you end up shaving by a light that makes you look ill\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023134560638,"sku":"BBM-FRP-011-P10","price":1324.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023134593406,"sku":"BBM-FRP-011-P20","price":2524.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023134626174,"sku":"BBM-FRP-011-P30","price":3649.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_CRI_97_in_Matt_Black.jpg?v=1789239738"},{"product_id":"fire-rated-airtight-ip65-downlight-trade-pack-in-matt-white","title":"Fire Rated Airtight IP65 Downlight Trade Pack in Matt White","description":"\u003cp\u003eA trade pack of fire rated downlights: airtight to less than 0.5 cubic metres an hour, which is what a passive house or an airtightness test needs and what a normal downlight destroys.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023134658942,"sku":"BBM-FRP-012-P10","price":1124.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023134691710,"sku":"BBM-FRP-012-P20","price":2149.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023134724478,"sku":"BBM-FRP-012-P30","price":3099.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_Airtight_IP65_Downlight_Trade_Pack_in_Matt_White.jpg?v=1789239738"},{"product_id":"fire-rated-airtight-ip65-downlight-trade-pack-in-brushed-chrome","title":"Fire Rated Airtight IP65 Downlight Trade Pack in Brushed Chrome","description":"\u003cp\u003eA trade pack of fire rated downlights: airtight to less than 0.5 cubic metres an hour, which is what a passive house or an airtightness test needs and what a normal downlight destroys.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023134757246,"sku":"BBM-FRP-013-P10","price":1224.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023134790014,"sku":"BBM-FRP-013-P20","price":2374.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023134822782,"sku":"BBM-FRP-013-P30","price":3399.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_Airtight_IP65_Downlight_Trade_Pack_in_Brushed_Chrome.jpg?v=1789239740"},{"product_id":"fire-rated-airtight-ip65-downlight-trade-pack-in-matt-black","title":"Fire Rated Airtight IP65 Downlight Trade Pack in Matt Black","description":"\u003cp\u003eA trade pack of fire rated downlights: airtight to less than 0.5 cubic metres an hour, which is what a passive house or an airtightness test needs and what a normal downlight destroys.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023134855550,"sku":"BBM-FRP-014-P10","price":1274.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023134888318,"sku":"BBM-FRP-014-P20","price":2424.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023134921086,"sku":"BBM-FRP-014-P30","price":3499.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_Airtight_IP65_Downlight_Trade_Pack_in_Matt_Black.jpg?v=1789239740"},{"product_id":"fire-rated-acoustic-ip65-downlight-trade-pack-in-matt-white","title":"Fire Rated Acoustic IP65 Downlight Trade Pack in Matt White","description":"\u003cp\u003eA trade pack of fire rated downlights: an acoustic hood integrated into the fitting, keeping a 45dB floor at 45dB, which matters in a flat and is a building control question.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023134953854,"sku":"BBM-FRP-015-P10","price":1274.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023134986622,"sku":"BBM-FRP-015-P20","price":2424.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023135019390,"sku":"BBM-FRP-015-P30","price":3499.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_Acoustic_IP65_Downlight_Trade_Pack_in_Matt_White.jpg?v=1789239740"},{"product_id":"fire-rated-acoustic-ip65-downlight-trade-pack-in-brushed-chrome","title":"Fire Rated Acoustic IP65 Downlight Trade Pack in Brushed Chrome","description":"\u003cp\u003eA trade pack of fire rated downlights: an acoustic hood integrated into the fitting, keeping a 45dB floor at 45dB, which matters in a flat and is a building control question.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.6 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023135052158,"sku":"BBM-FRP-016-P10","price":1374.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023135084926,"sku":"BBM-FRP-016-P20","price":2649.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023135117694,"sku":"BBM-FRP-016-P30","price":3824.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_Acoustic_IP65_Downlight_Trade_Pack_in_Brushed_Chrome.jpg?v=1789239740"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-adjustable-tilt-in-matt-white","title":"Fire Rated IP65 Downlight Trade Pack with Adjustable Tilt in Matt White","description":"\u003cp\u003eA trade pack of fire rated downlights: 30 degrees of tilt while staying IP65, which almost nothing manages, using a gimbal behind the gasket rather than in front of it.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023135150462,"sku":"BBM-FRP-017-P10","price":1224.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023135183230,"sku":"BBM-FRP-017-P20","price":2324.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023135215998,"sku":"BBM-FRP-017-P30","price":3349.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_Adjustable_Tilt_in_Matt_White.jpg?v=1789239732"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-adjustable-tilt-in-brushed-chrome","title":"Fire Rated IP65 Downlight Trade Pack with Adjustable Tilt in Brushed Chrome","description":"\u003cp\u003eA trade pack of fire rated downlights: 30 degrees of tilt while staying IP65, which almost nothing manages, using a gimbal behind the gasket rather than in front of it.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023135248766,"sku":"BBM-FRP-018-P10","price":1324.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023135281534,"sku":"BBM-FRP-018-P20","price":2549.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023135314302,"sku":"BBM-FRP-018-P30","price":3674.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_Adjustable_Tilt_in_Brushed_Chrome.jpg?v=1789239743"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-adjustable-tilt-in-matt-black","title":"Fire Rated IP65 Downlight Trade Pack with Adjustable Tilt in Matt Black","description":"\u003cp\u003eA trade pack of fire rated downlights: 30 degrees of tilt while staying IP65, which almost nothing manages, using a gimbal behind the gasket rather than in front of it.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023135347070,"sku":"BBM-FRP-019-P10","price":1374.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023135379838,"sku":"BBM-FRP-019-P20","price":2624.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023135412606,"sku":"BBM-FRP-019-P30","price":3799.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_Adjustable_Tilt_in_Matt_Black.jpg?v=1789239738"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-a-narrow-beam-in-brushed-chrome","title":"Fire Rated IP65 Downlight Trade Pack with a Narrow Beam in Brushed Chrome","description":"\u003cp\u003eA trade pack of fire rated downlights: a 24 degree beam for a three metre ceiling, because a 60 degree beam from that height gives you an evenly lit floor and a dark face.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023135543678,"sku":"BBM-FRP-021-P10","price":1274.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023135576446,"sku":"BBM-FRP-021-P20","price":2449.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023135609214,"sku":"BBM-FRP-021-P30","price":3549.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_a_Narrow_Beam_in_Brushed_Chrome.jpg?v=1789239742"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-a-narrow-beam-in-matt-black","title":"Fire Rated IP65 Downlight Trade Pack with a Narrow Beam in Matt Black","description":"\u003cp\u003eA trade pack of fire rated downlights: a 24 degree beam for a three metre ceiling, because a 60 degree beam from that height gives you an evenly lit floor and a dark face.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023135740286,"sku":"BBM-FRP-022-P10","price":1324.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023135773054,"sku":"BBM-FRP-022-P20","price":2524.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023135805822,"sku":"BBM-FRP-022-P30","price":3649.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_a_Narrow_Beam_in_Matt_Black.jpg?v=1789239740"},{"product_id":"fire-rated-ip65-downlight-trade-pack-with-dali-drivers-in-matt-white","title":"Fire Rated IP65 Downlight Trade Pack with DALI Drivers in Matt White","description":"\u003cp\u003eA trade pack of fire rated downlights: DALI 2 drivers for a job that will be commissioned, which is every commercial job and an increasing number of large houses.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall diameter, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens per fitting at 92 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: 3000K as standard, or selectable on the models that say so\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent without flicker or drop out\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21 fire testing with certificates for both plasterboard and timber joist constructions\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.5 kilograms per fitting\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003ePack: chosen above, and the price per fitting falls at twenty and again at thirty\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly with insulation, no hood required, which is the whole point of an integrated fire rated fitting\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, which clears a 47mm joist void and is the number that catches people out on a first floor bathroom\u003c\/li\u003e\n\u003cli\u003eCertificates: fire, IP and photometric test reports downloadable from this page rather than on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fittings, with integral drivers and flex tails\u003c\/li\u003e\n\u003cli\u003eIP65 rated push fit connectors\u003c\/li\u003e\n\u003cli\u003espare gaskets\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003efire and IP test certificates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The fitting is fire rated in itself, so no hood is needed and insulation may be laid straight over it. Check the 55mm insertion depth against your joist void before you cut the first hole, because a first floor bathroom ceiling with 47mm joists and a plasterboard skin is tighter than it looks.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eFire rating is not a nice to have. If the ceiling below the bathroom is a fire compartment, which it is in every flat and in most two storey houses where the room below is habitable, cutting an 85mm hole in it without a fire rated fitting or a hood breaches Part B of the Building Regulations. The certificate for these is on this page, for both plasterboard and timber joist constructions, because a fitting tested in only one of those is only rated in one of those.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"Pack of ten","offer_id":58023135871358,"sku":"BBM-FRP-023-P10","price":1299.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of twenty","offer_id":58023135904126,"sku":"BBM-FRP-023-P20","price":2524.0,"currency_code":"GBP","in_stock":true},{"title":"Pack of thirty","offer_id":58023135936894,"sku":"BBM-FRP-023-P30","price":3624.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Fire_Rated_IP65_Downlight_Trade_Pack_with_DALI_Drivers_in_Matt_White.jpg?v=1789239735"}],"url":"https:\/\/batheandbeam.com\/collections\/trade-packs.oembed","provider":"Bathe \u0026 Beam","version":"1.0","type":"link"}