{"title":"Downlights","description":"\u003cp\u003eRecessed ceiling lights, every one stating its IP rating, fire rating, CRI, beam angle and cut-out size. Check the void depth before you order — our slim range is 25mm deep for exactly that reason.\u003c\/p\u003e","products":[{"product_id":"ip65-fire-rated-downlight-in-matt-white","title":"IP65 Fire Rated Downlight in Matt White","description":"\u003cp\u003eA downlight for a bathroom: the one to buy if you are buying one thing: fire rated, IP65, integral driver, dimmable, and nothing clever.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 92 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.41 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023149076862,"sku":"BBM-DWN-001-27","price":29.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023149109630,"sku":"BBM-DWN-001-30","price":29.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023149142398,"sku":"BBM-DWN-001-40","price":29.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_in_Matt_White.jpg?v=1789239801"},{"product_id":"ip65-fire-rated-downlight-in-brushed-chrome","title":"IP65 Fire Rated Downlight in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: the one to buy if you are buying one thing: fire rated, IP65, integral driver, dimmable, and nothing clever.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 92 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023149175166,"sku":"BBM-DWN-002-27","price":32.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023149207934,"sku":"BBM-DWN-002-30","price":32.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023149240702,"sku":"BBM-DWN-002-40","price":32.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_in_Brushed_Chrome.jpg?v=1789239805"},{"product_id":"ip65-fire-rated-downlight-in-matt-black","title":"IP65 Fire Rated Downlight in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: the one to buy if you are buying one thing: fire rated, IP65, integral driver, dimmable, and nothing clever.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 92 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023149273470,"sku":"BBM-DWN-003-27","price":33.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023149306238,"sku":"BBM-DWN-003-30","price":33.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023149339006,"sku":"BBM-DWN-003-40","price":33.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_in_Matt_Black.jpg?v=1789239804"},{"product_id":"ip65-fire-rated-downlight-with-selectable-colour-temperature-in-matt-white","title":"IP65 Fire Rated Downlight with Selectable Colour Temperature in Matt White","description":"\u003cp\u003eA downlight for a bathroom: a switch on the back for 2700K, 3000K or 4000K, decided on site rather than in a basket.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.43 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023149470078,"sku":"BBM-DWN-005-27","price":35.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023149502846,"sku":"BBM-DWN-005-30","price":35.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023149535614,"sku":"BBM-DWN-005-40","price":35.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_Selectable_Colour_Temperature_in_Matt_White.jpg?v=1789239811"},{"product_id":"ip65-fire-rated-downlight-with-selectable-colour-temperature-in-brushed-chrome","title":"IP65 Fire Rated Downlight with Selectable Colour Temperature in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: a switch on the back for 2700K, 3000K or 4000K, decided on site rather than in a basket.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.44 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023149568382,"sku":"BBM-DWN-006-27","price":38.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023149601150,"sku":"BBM-DWN-006-30","price":38.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023149633918,"sku":"BBM-DWN-006-40","price":38.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_Selectable_Colour_Temperature_in_Brushed_Chrome.jpg?v=1789239813"},{"product_id":"ip65-fire-rated-downlight-with-selectable-colour-temperature-in-matt-black","title":"IP65 Fire Rated Downlight with Selectable Colour Temperature in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: a switch on the back for 2700K, 3000K or 4000K, decided on site rather than in a basket.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.44 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023149666686,"sku":"BBM-DWN-007-27","price":39.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023149699454,"sku":"BBM-DWN-007-30","price":39.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023149732222,"sku":"BBM-DWN-007-40","price":39.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_Selectable_Colour_Temperature_in_Matt_Black.jpg?v=1789239811"},{"product_id":"ip65-fire-rated-downlight-with-selectable-colour-temperature-in-polished-chrome","title":"IP65 Fire Rated Downlight with Selectable Colour Temperature in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: a switch on the back for 2700K, 3000K or 4000K, decided on site rather than in a basket.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.44 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023149764990,"sku":"BBM-DWN-008-27","price":37.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023149797758,"sku":"BBM-DWN-008-30","price":37.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023149830526,"sku":"BBM-DWN-008-40","price":37.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_Selectable_Colour_Temperature_in_Polished_Chrome.jpg?v=1789239812"},{"product_id":"ip65-fire-rated-downlight-with-dim-to-warm-in-matt-white","title":"IP65 Fire Rated Downlight with Dim to Warm in Matt White","description":"\u003cp\u003eA downlight for a bathroom: falls from 2700K to 1800K as it dims, which is what a halogen did and what people actually mean when they say they miss halogen.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 620 lumens at 86 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.43 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023149863294,"sku":"BBM-DWN-009-27","price":42.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023149896062,"sku":"BBM-DWN-009-30","price":42.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023149928830,"sku":"BBM-DWN-009-40","price":42.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_Dim_to_Warm_in_Matt_White.jpg?v=1789239811"},{"product_id":"ip65-fire-rated-downlight-with-dim-to-warm-in-brushed-chrome","title":"IP65 Fire Rated Downlight with Dim to Warm in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: falls from 2700K to 1800K as it dims, which is what a halogen did and what people actually mean when they say they miss halogen.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 620 lumens at 86 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.44 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023149994366,"sku":"BBM-DWN-010-27","price":46.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023150027134,"sku":"BBM-DWN-010-30","price":46.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023150059902,"sku":"BBM-DWN-010-40","price":46.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_Dim_to_Warm_in_Brushed_Chrome.jpg?v=1789239811"},{"product_id":"ip65-fire-rated-downlight-with-dim-to-warm-in-matt-black","title":"IP65 Fire Rated Downlight with Dim to Warm in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: falls from 2700K to 1800K as it dims, which is what a halogen did and what people actually mean when they say they miss halogen.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 620 lumens at 86 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.44 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023150125438,"sku":"BBM-DWN-011-27","price":48.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023150158206,"sku":"BBM-DWN-011-30","price":48.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023150190974,"sku":"BBM-DWN-011-40","price":48.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_Dim_to_Warm_in_Matt_Black.jpg?v=1789239812"},{"product_id":"ip65-fire-rated-downlight-with-dim-to-warm-in-polished-chrome","title":"IP65 Fire Rated Downlight with Dim to Warm in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: falls from 2700K to 1800K as it dims, which is what a halogen did and what people actually mean when they say they miss halogen.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 620 lumens at 86 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.44 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023150223742,"sku":"BBM-DWN-012-27","price":45.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023150256510,"sku":"BBM-DWN-012-30","price":45.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023150289278,"sku":"BBM-DWN-012-40","price":45.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_Dim_to_Warm_in_Polished_Chrome.jpg?v=1789239813"},{"product_id":"ip65-fire-rated-downlight-with-cri-97-in-matt-white","title":"IP65 Fire Rated Downlight with CRI 97 in Matt White","description":"\u003cp\u003eA downlight for a bathroom: CRI 97 with R9 above 90, which is a photographic specification and the difference between skin looking like skin and skin looking grey.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 610 lumens at 84 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 95, measured, with R9 above 60. R9 is the deep red value and it is the one that decides whether skin looks like skin. Most bathroom fittings quote a CRI in the eighties and do not quote R9 at all, which is how you end up shaving by a light that makes you look ill\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.41 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023150322046,"sku":"BBM-DWN-013-27","price":48.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023150354814,"sku":"BBM-DWN-013-30","price":48.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023150387582,"sku":"BBM-DWN-013-40","price":48.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_CRI_97_in_Matt_White.jpg?v=1789239812"},{"product_id":"ip65-fire-rated-downlight-with-cri-97-in-brushed-chrome","title":"IP65 Fire Rated Downlight with CRI 97 in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: CRI 97 with R9 above 90, which is a photographic specification and the difference between skin looking like skin and skin looking grey.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 610 lumens at 84 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 95, measured, with R9 above 60. R9 is the deep red value and it is the one that decides whether skin looks like skin. Most bathroom fittings quote a CRI in the eighties and do not quote R9 at all, which is how you end up shaving by a light that makes you look ill\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023150420350,"sku":"BBM-DWN-014-27","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023150453118,"sku":"BBM-DWN-014-30","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023150485886,"sku":"BBM-DWN-014-40","price":54.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_CRI_97_in_Brushed_Chrome.jpg?v=1789239813"},{"product_id":"ip65-fire-rated-downlight-with-cri-97-in-matt-black","title":"IP65 Fire Rated Downlight with CRI 97 in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: CRI 97 with R9 above 90, which is a photographic specification and the difference between skin looking like skin and skin looking grey.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 610 lumens at 84 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 95, measured, with R9 above 60. R9 is the deep red value and it is the one that decides whether skin looks like skin. Most bathroom fittings quote a CRI in the eighties and do not quote R9 at all, which is how you end up shaving by a light that makes you look ill\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023150518654,"sku":"BBM-DWN-015-27","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023150551422,"sku":"BBM-DWN-015-30","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023150584190,"sku":"BBM-DWN-015-40","price":54.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_CRI_97_in_Matt_Black.jpg?v=1789239810"},{"product_id":"ip65-fire-rated-downlight-with-cri-97-in-polished-chrome","title":"IP65 Fire Rated Downlight with CRI 97 in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: CRI 97 with R9 above 90, which is a photographic specification and the difference between skin looking like skin and skin looking grey.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 610 lumens at 84 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 95, measured, with R9 above 60. R9 is the deep red value and it is the one that decides whether skin looks like skin. Most bathroom fittings quote a CRI in the eighties and do not quote R9 at all, which is how you end up shaving by a light that makes you look ill\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023150616958,"sku":"BBM-DWN-016-27","price":49.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023150649726,"sku":"BBM-DWN-016-30","price":49.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023150682494,"sku":"BBM-DWN-016-40","price":49.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_CRI_97_in_Polished_Chrome.jpg?v=1789239813"},{"product_id":"ip65-fire-rated-airtight-downlight-in-matt-white","title":"IP65 Fire Rated Airtight Downlight in Matt White","description":"\u003cp\u003eA downlight for a bathroom: airtight to under 0.5 cubic metres an hour, for a house that has to pass an airtightness test or a ceiling you would rather not turn into a chimney.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.51 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023150715262,"sku":"BBM-DWN-017-27","price":40.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023150748030,"sku":"BBM-DWN-017-30","price":40.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023150780798,"sku":"BBM-DWN-017-40","price":40.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Airtight_Downlight_in_Matt_White.jpg?v=1789239804"},{"product_id":"ip65-fire-rated-airtight-downlight-in-brushed-chrome","title":"IP65 Fire Rated Airtight Downlight in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: airtight to under 0.5 cubic metres an hour, for a house that has to pass an airtightness test or a ceiling you would rather not turn into a chimney.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.52 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023150813566,"sku":"BBM-DWN-018-27","price":44.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023150846334,"sku":"BBM-DWN-018-30","price":44.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023150879102,"sku":"BBM-DWN-018-40","price":44.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Airtight_Downlight_in_Brushed_Chrome.jpg?v=1789239807"},{"product_id":"ip65-fire-rated-airtight-downlight-in-matt-black","title":"IP65 Fire Rated Airtight Downlight in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: airtight to under 0.5 cubic metres an hour, for a house that has to pass an airtightness test or a ceiling you would rather not turn into a chimney.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.52 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023150911870,"sku":"BBM-DWN-019-27","price":46.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023150944638,"sku":"BBM-DWN-019-30","price":46.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023150977406,"sku":"BBM-DWN-019-40","price":46.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Airtight_Downlight_in_Matt_Black.jpg?v=1789239804"},{"product_id":"ip65-fire-rated-airtight-downlight-in-polished-chrome","title":"IP65 Fire Rated Airtight Downlight in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: airtight to under 0.5 cubic metres an hour, for a house that has to pass an airtightness test or a ceiling you would rather not turn into a chimney.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.52 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151010174,"sku":"BBM-DWN-020-27","price":43.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023151042942,"sku":"BBM-DWN-020-30","price":43.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023151075710,"sku":"BBM-DWN-020-40","price":43.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Airtight_Downlight_in_Polished_Chrome.jpg?v=1789239807"},{"product_id":"ip65-fire-rated-acoustic-downlight-in-matt-white","title":"IP65 Fire Rated Acoustic Downlight in Matt White","description":"\u003cp\u003eA downlight for a bathroom: an integrated acoustic hood, so a 45dB floor between flats stays a 45dB floor.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 88 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.57 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151108478,"sku":"BBM-DWN-021-27","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023151141246,"sku":"BBM-DWN-021-30","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023151174014,"sku":"BBM-DWN-021-40","price":54.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Acoustic_Downlight_in_Matt_White.jpg?v=1789239804"},{"product_id":"ip65-fire-rated-acoustic-downlight-in-brushed-chrome","title":"IP65 Fire Rated Acoustic Downlight in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: an integrated acoustic hood, so a 45dB floor between flats stays a 45dB floor.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 88 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.58 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151206782,"sku":"BBM-DWN-022-27","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023151239550,"sku":"BBM-DWN-022-30","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023151272318,"sku":"BBM-DWN-022-40","price":59.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Acoustic_Downlight_in_Brushed_Chrome.jpg?v=1789239807"},{"product_id":"ip65-fire-rated-acoustic-downlight-in-matt-black","title":"IP65 Fire Rated Acoustic Downlight in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: an integrated acoustic hood, so a 45dB floor between flats stays a 45dB floor.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 88 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.58 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151305086,"sku":"BBM-DWN-023-27","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023151337854,"sku":"BBM-DWN-023-30","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023151370622,"sku":"BBM-DWN-023-40","price":59.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Acoustic_Downlight_in_Matt_Black.jpg?v=1789239804"},{"product_id":"ip65-fire-rated-acoustic-downlight-in-polished-chrome","title":"IP65 Fire Rated Acoustic Downlight in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: an integrated acoustic hood, so a 45dB floor between flats stays a 45dB floor.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 88 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.58 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151403390,"sku":"BBM-DWN-024-27","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023151436158,"sku":"BBM-DWN-024-30","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023151468926,"sku":"BBM-DWN-024-40","price":54.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Acoustic_Downlight_in_Polished_Chrome.jpg?v=1789239807"},{"product_id":"ip65-fire-rated-tilting-downlight-in-matt-white","title":"IP65 Fire Rated Tilting Downlight in Matt White","description":"\u003cp\u003eA downlight for a bathroom: 30 degrees of tilt while staying IP65, with the gimbal behind the gasket rather than in front of it, which is why almost nobody makes one.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 620 lumens at 86 lumens per circuit watt, 40 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.49 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 40 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151501694,"sku":"BBM-DWN-025-27","price":49.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023151534462,"sku":"BBM-DWN-025-30","price":49.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023151567230,"sku":"BBM-DWN-025-40","price":49.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Tilting_Downlight_in_Matt_White.jpg?v=1789239812"},{"product_id":"ip65-fire-rated-tilting-downlight-in-brushed-chrome","title":"IP65 Fire Rated Tilting Downlight in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: 30 degrees of tilt while staying IP65, with the gimbal behind the gasket rather than in front of it, which is why almost nobody makes one.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 620 lumens at 86 lumens per circuit watt, 40 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.50 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 40 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151599998,"sku":"BBM-DWN-026-27","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023151632766,"sku":"BBM-DWN-026-30","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023151665534,"sku":"BBM-DWN-026-40","price":54.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Tilting_Downlight_in_Brushed_Chrome.jpg?v=1789239812"},{"product_id":"ip65-fire-rated-tilting-downlight-in-matt-black","title":"IP65 Fire Rated Tilting Downlight in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: 30 degrees of tilt while staying IP65, with the gimbal behind the gasket rather than in front of it, which is why almost nobody makes one.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 620 lumens at 86 lumens per circuit watt, 40 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.50 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 40 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151698302,"sku":"BBM-DWN-027-27","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023151731070,"sku":"BBM-DWN-027-30","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023151763838,"sku":"BBM-DWN-027-40","price":54.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Tilting_Downlight_in_Matt_Black.jpg?v=1789239813"},{"product_id":"ip65-fire-rated-tilting-downlight-in-polished-chrome","title":"IP65 Fire Rated Tilting Downlight in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: 30 degrees of tilt while staying IP65, with the gimbal behind the gasket rather than in front of it, which is why almost nobody makes one.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 620 lumens at 86 lumens per circuit watt, 40 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.50 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 40 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151796606,"sku":"BBM-DWN-028-27","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023151829374,"sku":"BBM-DWN-028-30","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023151862142,"sku":"BBM-DWN-028-40","price":54.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Tilting_Downlight_in_Polished_Chrome.jpg?v=1789239812"},{"product_id":"ip65-fire-rated-downlight-with-a-narrow-beam-in-matt-white","title":"IP65 Fire Rated Downlight with a Narrow Beam in Matt White","description":"\u003cp\u003eA downlight for a bathroom: a 24 degree beam for a three metre ceiling, which lands as light rather than as pools.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 90 lumens per circuit watt, 24 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.41 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 24 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151894910,"sku":"BBM-DWN-029-27","price":44.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023151927678,"sku":"BBM-DWN-029-30","price":44.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023151960446,"sku":"BBM-DWN-029-40","price":44.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_a_Narrow_Beam_in_Matt_White.jpg?v=1789239807"},{"product_id":"ip65-fire-rated-downlight-with-a-narrow-beam-in-brushed-chrome","title":"IP65 Fire Rated Downlight with a Narrow Beam in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: a 24 degree beam for a three metre ceiling, which lands as light rather than as pools.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 90 lumens per circuit watt, 24 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 24 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023151993214,"sku":"BBM-DWN-030-27","price":48.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023152025982,"sku":"BBM-DWN-030-30","price":48.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023152058750,"sku":"BBM-DWN-030-40","price":48.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_a_Narrow_Beam_in_Brushed_Chrome.jpg?v=1789239812"},{"product_id":"ip65-fire-rated-downlight-with-a-narrow-beam-in-matt-black","title":"IP65 Fire Rated Downlight with a Narrow Beam in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: a 24 degree beam for a three metre ceiling, which lands as light rather than as pools.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 90 lumens per circuit watt, 24 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 24 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023152091518,"sku":"BBM-DWN-031-27","price":49.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023152124286,"sku":"BBM-DWN-031-30","price":49.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023152157054,"sku":"BBM-DWN-031-40","price":49.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_a_Narrow_Beam_in_Matt_Black.jpg?v=1789239807"},{"product_id":"ip65-fire-rated-downlight-with-a-narrow-beam-in-polished-chrome","title":"IP65 Fire Rated Downlight with a Narrow Beam in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: a 24 degree beam for a three metre ceiling, which lands as light rather than as pools.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 90 lumens per circuit watt, 24 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 24 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023152189822,"sku":"BBM-DWN-032-27","price":47.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023152222590,"sku":"BBM-DWN-032-30","price":47.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023152255358,"sku":"BBM-DWN-032-40","price":47.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_a_Narrow_Beam_in_Polished_Chrome.jpg?v=1789239807"},{"product_id":"ip65-fire-rated-downlight-with-a-wide-beam-in-matt-white","title":"IP65 Fire Rated Downlight with a Wide Beam in Matt White","description":"\u003cp\u003eA downlight for a bathroom: a 90 degree beam for a low ceiling, where a narrow beam makes a small bathroom look like a car park at night.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 660 lumens at 92 lumens per circuit watt, 90 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.41 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 90 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023152288126,"sku":"BBM-DWN-033-27","price":35.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023152320894,"sku":"BBM-DWN-033-30","price":35.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023152353662,"sku":"BBM-DWN-033-40","price":35.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_a_Wide_Beam_in_Matt_White.jpg?v=1789239807"},{"product_id":"ip65-fire-rated-downlight-with-a-wide-beam-in-brushed-chrome","title":"IP65 Fire Rated Downlight with a Wide Beam in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: a 90 degree beam for a low ceiling, where a narrow beam makes a small bathroom look like a car park at night.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 660 lumens at 92 lumens per circuit watt, 90 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 90 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023152419198,"sku":"BBM-DWN-034-27","price":38.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023152451966,"sku":"BBM-DWN-034-30","price":38.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023152484734,"sku":"BBM-DWN-034-40","price":38.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_a_Wide_Beam_in_Brushed_Chrome.jpg?v=1789239812"},{"product_id":"ip65-fire-rated-downlight-with-a-wide-beam-in-matt-black","title":"IP65 Fire Rated Downlight with a Wide Beam in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: a 90 degree beam for a low ceiling, where a narrow beam makes a small bathroom look like a car park at night.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 660 lumens at 92 lumens per circuit watt, 90 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 90 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023152517502,"sku":"BBM-DWN-035-27","price":39.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023152550270,"sku":"BBM-DWN-035-30","price":39.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023152583038,"sku":"BBM-DWN-035-40","price":39.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_a_Wide_Beam_in_Matt_Black.jpg?v=1789239804"},{"product_id":"ip65-fire-rated-downlight-with-a-wide-beam-in-polished-chrome","title":"IP65 Fire Rated Downlight with a Wide Beam in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: a 90 degree beam for a low ceiling, where a narrow beam makes a small bathroom look like a car park at night.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 660 lumens at 92 lumens per circuit watt, 90 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.42 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 90 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023152615806,"sku":"BBM-DWN-036-27","price":37.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023152648574,"sku":"BBM-DWN-036-30","price":37.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023152681342,"sku":"BBM-DWN-036-40","price":37.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_a_Wide_Beam_in_Polished_Chrome.jpg?v=1789239807"},{"product_id":"slim-ip65-downlight-at-25mm-deep-in-matt-white","title":"Slim IP65 Downlight at 25mm Deep in Matt White","description":"\u003cp\u003eA downlight for a bathroom: 25mm above the ceiling with a remote driver, for a concrete soffit or a void that does not exist.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 40mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 580 lumens at 84 lumens per circuit watt, 110 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2 with a remote driver on a 2 metre lead, which has to be accessible for maintenance. Plan a hatch or place it in the loft, because a driver buried in a sealed void is a fault waiting to happen\u003c\/li\u003e\n\u003cli\u003eFire rating: not fire rated. If the ceiling below is a fire compartment, which it is in a flat and in most two storey extensions, this fitting needs a fire hood or a different product\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.29 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: must not be covered. This fitting is not fire rated and needs a hood in a fire compartment ceiling\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 40mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 110 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023152714110,"sku":"BBM-DWN-037-27","price":38.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023152746878,"sku":"BBM-DWN-037-30","price":38.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023152779646,"sku":"BBM-DWN-037-40","price":38.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Slim_IP65_Downlight_at_25mm_Deep_in_Matt_White.jpg?v=1789239869"},{"product_id":"slim-ip65-downlight-at-25mm-deep-in-brushed-chrome","title":"Slim IP65 Downlight at 25mm Deep in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: 25mm above the ceiling with a remote driver, for a concrete soffit or a void that does not exist.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 40mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 580 lumens at 84 lumens per circuit watt, 110 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2 with a remote driver on a 2 metre lead, which has to be accessible for maintenance. Plan a hatch or place it in the loft, because a driver buried in a sealed void is a fault waiting to happen\u003c\/li\u003e\n\u003cli\u003eFire rating: not fire rated. If the ceiling below is a fire compartment, which it is in a flat and in most two storey extensions, this fitting needs a fire hood or a different product\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.30 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: must not be covered. This fitting is not fire rated and needs a hood in a fire compartment ceiling\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 40mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 110 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023152812414,"sku":"BBM-DWN-038-27","price":42.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023152845182,"sku":"BBM-DWN-038-30","price":42.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023152877950,"sku":"BBM-DWN-038-40","price":42.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Slim_IP65_Downlight_at_25mm_Deep_in_Brushed_Chrome.jpg?v=1789239872"},{"product_id":"slim-ip65-downlight-at-25mm-deep-in-matt-black","title":"Slim IP65 Downlight at 25mm Deep in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: 25mm above the ceiling with a remote driver, for a concrete soffit or a void that does not exist.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 40mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 580 lumens at 84 lumens per circuit watt, 110 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2 with a remote driver on a 2 metre lead, which has to be accessible for maintenance. Plan a hatch or place it in the loft, because a driver buried in a sealed void is a fault waiting to happen\u003c\/li\u003e\n\u003cli\u003eFire rating: not fire rated. If the ceiling below is a fire compartment, which it is in a flat and in most two storey extensions, this fitting needs a fire hood or a different product\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.30 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: must not be covered. This fitting is not fire rated and needs a hood in a fire compartment ceiling\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 40mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 110 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023152910718,"sku":"BBM-DWN-039-27","price":44.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023152943486,"sku":"BBM-DWN-039-30","price":44.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023152976254,"sku":"BBM-DWN-039-40","price":44.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Slim_IP65_Downlight_at_25mm_Deep_in_Matt_Black.jpg?v=1789239871"},{"product_id":"slim-ip65-downlight-at-25mm-deep-in-polished-chrome","title":"Slim IP65 Downlight at 25mm Deep in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: 25mm above the ceiling with a remote driver, for a concrete soffit or a void that does not exist.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 40mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 580 lumens at 84 lumens per circuit watt, 110 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2 with a remote driver on a 2 metre lead, which has to be accessible for maintenance. Plan a hatch or place it in the loft, because a driver buried in a sealed void is a fault waiting to happen\u003c\/li\u003e\n\u003cli\u003eFire rating: not fire rated. If the ceiling below is a fire compartment, which it is in a flat and in most two storey extensions, this fitting needs a fire hood or a different product\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.30 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: must not be covered. This fitting is not fire rated and needs a hood in a fire compartment ceiling\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 40mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 110 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023153041790,"sku":"BBM-DWN-040-27","price":41.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023153074558,"sku":"BBM-DWN-040-30","price":41.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023153107326,"sku":"BBM-DWN-040-40","price":41.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Slim_IP65_Downlight_at_25mm_Deep_in_Polished_Chrome.jpg?v=1789239873"},{"product_id":"ip65-downlight-with-a-remote-driver-in-matt-white","title":"IP65 Downlight with a Remote Driver in Matt White","description":"\u003cp\u003eA downlight for a bathroom: a remote driver on a 2 metre lead, which has to be accessible, and we would rather you planned for that than discovered it.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2 with a remote driver on a 2 metre lead, which has to be accessible for maintenance. Plan a hatch or place it in the loft, because a driver buried in a sealed void is a fault waiting to happen\u003c\/li\u003e\n\u003cli\u003eFire rating: not fire rated. If the ceiling below is a fire compartment, which it is in a flat and in most two storey extensions, this fitting needs a fire hood or a different product\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.45 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: must not be covered. This fitting is not fire rated and needs a hood in a fire compartment ceiling\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023153140094,"sku":"BBM-DWN-041-27","price":33.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023153172862,"sku":"BBM-DWN-041-30","price":33.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023153205630,"sku":"BBM-DWN-041-40","price":33.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Downlight_with_a_Remote_Driver_in_Matt_White.jpg?v=1789239807"},{"product_id":"ip65-downlight-with-a-remote-driver-in-brushed-chrome","title":"IP65 Downlight with a Remote Driver in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: a remote driver on a 2 metre lead, which has to be accessible, and we would rather you planned for that than discovered it.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2 with a remote driver on a 2 metre lead, which has to be accessible for maintenance. Plan a hatch or place it in the loft, because a driver buried in a sealed void is a fault waiting to happen\u003c\/li\u003e\n\u003cli\u003eFire rating: not fire rated. If the ceiling below is a fire compartment, which it is in a flat and in most two storey extensions, this fitting needs a fire hood or a different product\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.46 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: must not be covered. This fitting is not fire rated and needs a hood in a fire compartment ceiling\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023153238398,"sku":"BBM-DWN-042-27","price":36.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023153271166,"sku":"BBM-DWN-042-30","price":36.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023153303934,"sku":"BBM-DWN-042-40","price":36.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Downlight_with_a_Remote_Driver_in_Brushed_Chrome.jpg?v=1789239807"},{"product_id":"ip65-downlight-with-a-remote-driver-in-matt-black","title":"IP65 Downlight with a Remote Driver in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: a remote driver on a 2 metre lead, which has to be accessible, and we would rather you planned for that than discovered it.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2 with a remote driver on a 2 metre lead, which has to be accessible for maintenance. Plan a hatch or place it in the loft, because a driver buried in a sealed void is a fault waiting to happen\u003c\/li\u003e\n\u003cli\u003eFire rating: not fire rated. If the ceiling below is a fire compartment, which it is in a flat and in most two storey extensions, this fitting needs a fire hood or a different product\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.46 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: must not be covered. This fitting is not fire rated and needs a hood in a fire compartment ceiling\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023153336702,"sku":"BBM-DWN-043-27","price":37.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023153369470,"sku":"BBM-DWN-043-30","price":37.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023153402238,"sku":"BBM-DWN-043-40","price":37.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Downlight_with_a_Remote_Driver_in_Matt_Black.jpg?v=1789239804"},{"product_id":"ip65-downlight-with-a-remote-driver-in-polished-chrome","title":"IP65 Downlight with a Remote Driver in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: a remote driver on a 2 metre lead, which has to be accessible, and we would rather you planned for that than discovered it.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 650 lumens at 90 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2 with a remote driver on a 2 metre lead, which has to be accessible for maintenance. Plan a hatch or place it in the loft, because a driver buried in a sealed void is a fault waiting to happen\u003c\/li\u003e\n\u003cli\u003eFire rating: not fire rated. If the ceiling below is a fire compartment, which it is in a flat and in most two storey extensions, this fitting needs a fire hood or a different product\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.46 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: must not be covered. This fitting is not fire rated and needs a hood in a fire compartment ceiling\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023153435006,"sku":"BBM-DWN-044-27","price":35.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023153467774,"sku":"BBM-DWN-044-30","price":35.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023153500542,"sku":"BBM-DWN-044-40","price":35.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Downlight_with_a_Remote_Driver_in_Polished_Chrome.jpg?v=1789239809"},{"product_id":"ip67-selv-floor-light-for-zone-0-in-matt-black","title":"IP67 SELV Floor Light for Zone 0 in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: a 12 volt floor light rated for temporary immersion, which is the only kind of fitting that may go inside a shower tray or a bath surround.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 0, which is inside the bath or the shower tray itself. A fitting here must be IP67 and must run at SELV, meaning 12 volts or less with the transformer outside the zones\u003c\/li\u003e\n\u003cli\u003eIP rating: IP67. Dust tight and protected against temporary immersion in up to a metre of water, which is what zone 0 requires and what a fitting in a shower tray or a bath surround has to be\u003c\/li\u003e\n\u003cli\u003eDimensions: 68mm cut out, 75mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 180 lumens at 68 lumens per circuit watt, 45 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: SELV, 12 volts, with the transformer sited outside the zones. This is what makes the fitting legal in zone 0 and it is not optional\u003c\/li\u003e\n\u003cli\u003eFire rating: not fire rated. If the ceiling below is a fire compartment, which it is in a flat and in most two storey extensions, this fitting needs a fire hood or a different product\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.36 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: must not be covered. This fitting is not fire rated and needs a hood in a fire compartment ceiling\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 45 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023153729918,"sku":"BBM-DWN-047-27","price":84.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023153762686,"sku":"BBM-DWN-047-30","price":84.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023153795454,"sku":"BBM-DWN-047-40","price":84.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP67_SELV_Floor_Light_for_Zone_0_in_Matt_Black.jpg?v=1789239860"},{"product_id":"ip67-selv-floor-light-for-zone-0-in-polished-chrome","title":"IP67 SELV Floor Light for Zone 0 in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: a 12 volt floor light rated for temporary immersion, which is the only kind of fitting that may go inside a shower tray or a bath surround.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 0, which is inside the bath or the shower tray itself. A fitting here must be IP67 and must run at SELV, meaning 12 volts or less with the transformer outside the zones\u003c\/li\u003e\n\u003cli\u003eIP rating: IP67. Dust tight and protected against temporary immersion in up to a metre of water, which is what zone 0 requires and what a fitting in a shower tray or a bath surround has to be\u003c\/li\u003e\n\u003cli\u003eDimensions: 68mm cut out, 75mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 180 lumens at 68 lumens per circuit watt, 45 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: SELV, 12 volts, with the transformer sited outside the zones. This is what makes the fitting legal in zone 0 and it is not optional\u003c\/li\u003e\n\u003cli\u003eFire rating: not fire rated. If the ceiling below is a fire compartment, which it is in a flat and in most two storey extensions, this fitting needs a fire hood or a different product\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.36 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: must not be covered. This fitting is not fire rated and needs a hood in a fire compartment ceiling\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 45 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023153828222,"sku":"BBM-DWN-048-27","price":79.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023153860990,"sku":"BBM-DWN-048-30","price":79.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023153893758,"sku":"BBM-DWN-048-40","price":79.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP67_SELV_Floor_Light_for_Zone_0_in_Polished_Chrome.jpg?v=1789239861"},{"product_id":"ip65-fire-rated-downlight-with-dali-dimming-in-matt-white","title":"IP65 Fire Rated Downlight with DALI Dimming in Matt White","description":"\u003cp\u003eA downlight for a bathroom: a DALI 2 driver for a job that will be commissioned rather than switched.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 88 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: DALI 2 addressable\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.47 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023153926526,"sku":"BBM-DWN-049-27","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023153959294,"sku":"BBM-DWN-049-30","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023153992062,"sku":"BBM-DWN-049-40","price":59.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_DALI_Dimming_in_Matt_White.jpg?v=1789239808"},{"product_id":"ip65-fire-rated-downlight-with-dali-dimming-in-brushed-chrome","title":"IP65 Fire Rated Downlight with DALI Dimming in Brushed Chrome","description":"\u003cp\u003eA downlight for a bathroom: a DALI 2 driver for a job that will be commissioned rather than switched.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 88 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: DALI 2 addressable\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.48 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023154286974,"sku":"BBM-DWN-050-27","price":64.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023154319742,"sku":"BBM-DWN-050-30","price":64.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023154352510,"sku":"BBM-DWN-050-40","price":64.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_DALI_Dimming_in_Brushed_Chrome.jpg?v=1789239810"},{"product_id":"ip65-fire-rated-downlight-with-dali-dimming-in-matt-black","title":"IP65 Fire Rated Downlight with DALI Dimming in Matt Black","description":"\u003cp\u003eA downlight for a bathroom: a DALI 2 driver for a job that will be commissioned rather than switched.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 88 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: DALI 2 addressable\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.48 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023154385278,"sku":"BBM-DWN-051-27","price":64.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023154418046,"sku":"BBM-DWN-051-30","price":64.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023154450814,"sku":"BBM-DWN-051-40","price":64.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_DALI_Dimming_in_Matt_Black.jpg?v=1789239810"},{"product_id":"ip65-fire-rated-downlight-with-dali-dimming-in-polished-chrome","title":"IP65 Fire Rated Downlight with DALI Dimming in Polished Chrome","description":"\u003cp\u003eA downlight for a bathroom: a DALI 2 driver for a job that will be commissioned rather than switched.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 640 lumens at 88 lumens per circuit watt, 60 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: DALI 2 addressable\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.48 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: triple plated polished chrome over brass, which is the finish that survives a bathroom because the copper and nickel layers underneath are what actually stop corrosion\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 60 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023154483582,"sku":"BBM-DWN-052-27","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023154516350,"sku":"BBM-DWN-052-30","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023154549118,"sku":"BBM-DWN-052-40","price":59.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_DALI_Dimming_in_Polished_Chrome.jpg?v=1789239810"},{"product_id":"ip65-fire-rated-downlight-with-an-anti-glare-baffle-in-matt-white","title":"IP65 Fire Rated Downlight with an Anti Glare Baffle in Matt White","description":"\u003cp\u003eA downlight for a bathroom: a deep black baffle that puts the source out of sight from a normal standing position, which is what stops a bathroom ceiling looking like an interrogation.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 85mm cut out, 92mm overall, 55mm insertion depth above the ceiling\u003c\/li\u003e\n\u003cli\u003eLight output: 600 lumens at 84 lumens per circuit watt, 45 degree beam. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge, to 1 per cent\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: fire rated to 30, 60 and 90 minutes, tested to BS 476 Part 21 in both plasterboard and timber joist constructions, and the test certificate is downloadable from this page\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked, plus BS 476 Part 21\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.45 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: seven years on the fitting, the LED module and the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eInsulation: may be covered directly, no hood needed\u003c\/li\u003e\n\u003cli\u003eInsertion depth: 55mm, and this is the figure that decides whether it fits your joist void\u003c\/li\u003e\n\u003cli\u003eBeam angle: 45 degrees\u003c\/li\u003e\n\u003cli\u003eGasket: silicone, captive, replaceable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe downlight with its driver and flex tail\u003c\/li\u003e\n\u003cli\u003ean IP65 push fit connector\u003c\/li\u003e\n\u003cli\u003ea spare gasket\u003c\/li\u003e\n\u003cli\u003ea cut out template\u003c\/li\u003e\n\u003cli\u003etest certificates by download\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. Check the insertion depth against your void before cutting, and lay the cut outs out from the basin and the bath rather than evenly across the ceiling, because an evenly spaced grid reliably puts a light directly behind the person using the mirror.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eThree specifications decide a bathroom downlight and only one of them is usually printed on the box. IP65 rather than IP44 if it is going in zone 1, which is over the bath or in the shower. Fire rated if the ceiling is a fire compartment, which it is in every flat. And beam angle, which should be narrow for a high ceiling and wide for a low one. Lumens matter far less than any of those, and colour rendering matters more than lumens.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023154581886,"sku":"BBM-DWN-053-27","price":42.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023154614654,"sku":"BBM-DWN-053-30","price":42.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023154647422,"sku":"BBM-DWN-053-40","price":42.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Fire_Rated_Downlight_with_an_Anti_Glare_Baffle_in_Matt_White.jpg?v=1789239805"}],"url":"https:\/\/batheandbeam.com\/collections\/downlights.oembed","provider":"Bathe \u0026 Beam","version":"1.0","type":"link"}