{"title":"Ceiling Lights","description":"\u003cp\u003eSurface-mounted flush and semi-flush fittings for ceilings too shallow to recess into, or where you would rather not cut a hole in a fire barrier at all.\u003c\/p\u003e","products":[{"product_id":"ip44-flush-bathroom-ceiling-light-in-matt-white","title":"IP44 Flush Bathroom Ceiling Light in Matt White","description":"\u003cp\u003eA surface mounted bathroom light: the plain flush fitting that most bathrooms actually need, with an opal diffuser and a captive gasket.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1450 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.2 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023154975102,"sku":"BBM-CEI-001-27","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023155007870,"sku":"BBM-CEI-001-30","price":54.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023155040638,"sku":"BBM-CEI-001-40","price":54.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Flush_Bathroom_Ceiling_Light_in_Matt_White.jpg?v=1789239799"},{"product_id":"ip44-flush-bathroom-ceiling-light-in-brushed-chrome","title":"IP44 Flush Bathroom Ceiling Light in Brushed Chrome","description":"\u003cp\u003eA surface mounted bathroom light: the plain flush fitting that most bathrooms actually need, with an opal diffuser and a captive gasket.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1450 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.2 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023155073406,"sku":"BBM-CEI-002-27","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023155106174,"sku":"BBM-CEI-002-30","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023155138942,"sku":"BBM-CEI-002-40","price":59.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Flush_Bathroom_Ceiling_Light_in_Brushed_Chrome.jpg?v=1789239814"},{"product_id":"ip44-flush-bathroom-ceiling-light-in-matt-black","title":"IP44 Flush Bathroom Ceiling Light in Matt Black","description":"\u003cp\u003eA surface mounted bathroom light: the plain flush fitting that most bathrooms actually need, with an opal diffuser and a captive gasket.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1450 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.2 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023155171710,"sku":"BBM-CEI-003-27","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023155204478,"sku":"BBM-CEI-003-30","price":59.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023155237246,"sku":"BBM-CEI-003-40","price":59.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Flush_Bathroom_Ceiling_Light_in_Matt_Black.jpg?v=1789239799"},{"product_id":"ip65-flush-bathroom-ceiling-light-for-zone-1-in-brushed-chrome","title":"IP65 Flush Bathroom Ceiling Light for Zone 1 in Brushed Chrome","description":"\u003cp\u003eA surface mounted bathroom light: the same idea rated for directly above a bath, which is a different gasket and a different lens rather than a different sticker.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1600 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.4 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023155368318,"sku":"BBM-CEI-005-27","price":79.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023155401086,"sku":"BBM-CEI-005-30","price":79.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023155433854,"sku":"BBM-CEI-005-40","price":79.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Flush_Bathroom_Ceiling_Light_for_Zone_1_in_Brushed_Chrome.jpg?v=1789239812"},{"product_id":"ip65-flush-bathroom-ceiling-light-for-zone-1-in-matt-black","title":"IP65 Flush Bathroom Ceiling Light for Zone 1 in Matt Black","description":"\u003cp\u003eA surface mounted bathroom light: the same idea rated for directly above a bath, which is a different gasket and a different lens rather than a different sticker.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1600 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.4 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023155466622,"sku":"BBM-CEI-006-27","price":84.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023155499390,"sku":"BBM-CEI-006-30","price":84.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023155532158,"sku":"BBM-CEI-006-40","price":84.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Flush_Bathroom_Ceiling_Light_for_Zone_1_in_Matt_Black.jpg?v=1789239812"},{"product_id":"ip44-flush-ceiling-light-with-a-microwave-sensor-in-brushed-chrome","title":"IP44 Flush Ceiling Light with a Microwave Sensor in Brushed Chrome","description":"\u003cp\u003eA surface mounted bathroom light: a microwave sensor that sees through the diffuser, with an adjustable hold time, for a cloakroom or a landing.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1450 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.5 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: microwave, 360 degrees, with hold time and lux level adjustable on the back\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023155663230,"sku":"BBM-CEI-008-27","price":99.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023155695998,"sku":"BBM-CEI-008-30","price":99.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023155728766,"sku":"BBM-CEI-008-40","price":99.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Flush_Ceiling_Light_with_a_Microwave_Sensor_in_Brushed_Chrome.jpg?v=1789239811"},{"product_id":"ip44-flush-ceiling-light-with-a-microwave-sensor-in-matt-black","title":"IP44 Flush Ceiling Light with a Microwave Sensor in Matt Black","description":"\u003cp\u003eA surface mounted bathroom light: a microwave sensor that sees through the diffuser, with an adjustable hold time, for a cloakroom or a landing.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1450 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.5 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: microwave, 360 degrees, with hold time and lux level adjustable on the back\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023155761534,"sku":"BBM-CEI-009-27","price":99.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023155794302,"sku":"BBM-CEI-009-30","price":99.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023155827070,"sku":"BBM-CEI-009-40","price":99.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Flush_Ceiling_Light_with_a_Microwave_Sensor_in_Matt_Black.jpg?v=1789239802"},{"product_id":"ip65-flush-ceiling-light-with-an-emergency-module-in-matt-white","title":"IP65 Flush Ceiling Light with an Emergency Module in Matt White","description":"\u003cp\u003eA surface mounted bathroom light: a three hour maintained emergency module built in, which is what a communal bathroom or a let with a fire risk assessment will need.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1500 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.9 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023155859838,"sku":"BBM-CEI-010-27","price":119.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023155892606,"sku":"BBM-CEI-010-30","price":119.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023155925374,"sku":"BBM-CEI-010-40","price":119.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Flush_Ceiling_Light_with_an_Emergency_Module_in_Matt_White.jpg?v=1789239812"},{"product_id":"ip65-flush-ceiling-light-with-an-emergency-module-in-matt-black","title":"IP65 Flush Ceiling Light with an Emergency Module in Matt Black","description":"\u003cp\u003eA surface mounted bathroom light: a three hour maintained emergency module built in, which is what a communal bathroom or a let with a fire risk assessment will need.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1500 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.9 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023156056446,"sku":"BBM-CEI-012-27","price":134.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023156089214,"sku":"BBM-CEI-012-30","price":134.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023156121982,"sku":"BBM-CEI-012-40","price":134.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP65_Flush_Ceiling_Light_with_an_Emergency_Module_in_Matt_Black.jpg?v=1789239811"},{"product_id":"ip44-flush-ceiling-light-with-selectable-wattage-in-matt-white","title":"IP44 Flush Ceiling Light with Selectable Wattage in Matt White","description":"\u003cp\u003eA surface mounted bathroom light: a switch that selects 12W, 18W or 24W, so one fitting covers a cloakroom and a family bathroom.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1800 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.4 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023156154750,"sku":"BBM-CEI-013-27","price":74.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023156187518,"sku":"BBM-CEI-013-30","price":74.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023156220286,"sku":"BBM-CEI-013-40","price":74.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Flush_Ceiling_Light_with_Selectable_Wattage_in_Matt_White.jpg?v=1789239799"},{"product_id":"ip44-flush-ceiling-light-with-selectable-wattage-in-brushed-chrome","title":"IP44 Flush Ceiling Light with Selectable Wattage in Brushed Chrome","description":"\u003cp\u003eA surface mounted bathroom light: a switch that selects 12W, 18W or 24W, so one fitting covers a cloakroom and a family bathroom.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1800 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.4 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023156253054,"sku":"BBM-CEI-014-27","price":84.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023156285822,"sku":"BBM-CEI-014-30","price":84.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023156318590,"sku":"BBM-CEI-014-40","price":84.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Flush_Ceiling_Light_with_Selectable_Wattage_in_Brushed_Chrome.jpg?v=1789239806"},{"product_id":"ip44-flush-ceiling-light-with-selectable-wattage-in-matt-black","title":"IP44 Flush Ceiling Light with Selectable Wattage in Matt Black","description":"\u003cp\u003eA surface mounted bathroom light: a switch that selects 12W, 18W or 24W, so one fitting covers a cloakroom and a family bathroom.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1800 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.4 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023156351358,"sku":"BBM-CEI-015-27","price":84.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023156384126,"sku":"BBM-CEI-015-30","price":84.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023156416894,"sku":"BBM-CEI-015-40","price":84.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Flush_Ceiling_Light_with_Selectable_Wattage_in_Matt_Black.jpg?v=1789239802"},{"product_id":"slim-ip44-ceiling-light-at-25mm-deep-in-brushed-chrome","title":"Slim IP44 Ceiling Light at 25mm Deep in Brushed Chrome","description":"\u003cp\u003eA surface mounted bathroom light: 25mm deep, for a ceiling with no void at all.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 25mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1300 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.9 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023156547966,"sku":"BBM-CEI-017-27","price":69.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023156580734,"sku":"BBM-CEI-017-30","price":69.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023156613502,"sku":"BBM-CEI-017-40","price":69.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Slim_IP44_Ceiling_Light_at_25mm_Deep_in_Brushed_Chrome.jpg?v=1789239871"},{"product_id":"slim-ip44-ceiling-light-at-25mm-deep-in-matt-black","title":"Slim IP44 Ceiling Light at 25mm Deep in Matt Black","description":"\u003cp\u003eA surface mounted bathroom light: 25mm deep, for a ceiling with no void at all.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 25mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1300 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 0.9 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023156679038,"sku":"BBM-CEI-018-27","price":69.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023156711806,"sku":"BBM-CEI-018-30","price":69.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023156744574,"sku":"BBM-CEI-018-40","price":69.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Slim_IP44_Ceiling_Light_at_25mm_Deep_in_Matt_Black.jpg?v=1789239869"},{"product_id":"ip44-ceiling-light-with-a-fabric-diffuser-in-matt-white","title":"IP44 Ceiling Light with a Fabric Diffuser in Matt White","description":"\u003cp\u003eA surface mounted bathroom light: a moisture resistant fabric diffuser for a bathroom outside the zones, where the fitting can be softer than a plastic disc.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1250 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.6 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023156777342,"sku":"BBM-CEI-019-27","price":89.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023156810110,"sku":"BBM-CEI-019-30","price":89.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023156842878,"sku":"BBM-CEI-019-40","price":89.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Ceiling_Light_with_a_Fabric_Diffuser_in_Matt_White.jpg?v=1789239802"},{"product_id":"ip44-ceiling-light-with-a-fabric-diffuser-in-brushed-chrome","title":"IP44 Ceiling Light with a Fabric Diffuser in Brushed Chrome","description":"\u003cp\u003eA surface mounted bathroom light: a moisture resistant fabric diffuser for a bathroom outside the zones, where the fitting can be softer than a plastic disc.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1250 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.6 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023156875646,"sku":"BBM-CEI-020-27","price":99.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023156908414,"sku":"BBM-CEI-020-30","price":99.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023156941182,"sku":"BBM-CEI-020-40","price":99.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Ceiling_Light_with_a_Fabric_Diffuser_in_Brushed_Chrome.jpg?v=1789239811"},{"product_id":"ip44-ceiling-light-with-a-fabric-diffuser-in-matt-black","title":"IP44 Ceiling Light with a Fabric Diffuser in Matt Black","description":"\u003cp\u003eA surface mounted bathroom light: a moisture resistant fabric diffuser for a bathroom outside the zones, where the fitting can be softer than a plastic disc.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1250 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.6 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023156973950,"sku":"BBM-CEI-021-27","price":99.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023157006718,"sku":"BBM-CEI-021-30","price":99.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023157039486,"sku":"BBM-CEI-021-40","price":99.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Ceiling_Light_with_a_Fabric_Diffuser_in_Matt_Black.jpg?v=1789239801"},{"product_id":"large-ip65-ceiling-light-at-400mm-in-matt-white","title":"Large IP65 Ceiling Light at 400mm in Matt White","description":"\u003cp\u003eA surface mounted bathroom light: a 400mm fitting for a large bathroom, which does the work of four downlights with one hole in the ceiling.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 400mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 2800 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 2.5 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023157072254,"sku":"BBM-CEI-022-27","price":129.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023157105022,"sku":"BBM-CEI-022-30","price":129.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023157137790,"sku":"BBM-CEI-022-40","price":129.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Large_IP65_Ceiling_Light_at_400mm_in_Matt_White.jpg?v=1789239860"},{"product_id":"large-ip65-ceiling-light-at-400mm-in-brushed-chrome","title":"Large IP65 Ceiling Light at 400mm in Brushed Chrome","description":"\u003cp\u003eA surface mounted bathroom light: a 400mm fitting for a large bathroom, which does the work of four downlights with one hole in the ceiling.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 400mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 2800 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 2.6 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023157170558,"sku":"BBM-CEI-023-27","price":139.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023157203326,"sku":"BBM-CEI-023-30","price":139.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023157236094,"sku":"BBM-CEI-023-40","price":139.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Large_IP65_Ceiling_Light_at_400mm_in_Brushed_Chrome.jpg?v=1789239861"},{"product_id":"large-ip65-ceiling-light-at-400mm-in-matt-black","title":"Large IP65 Ceiling Light at 400mm in Matt Black","description":"\u003cp\u003eA surface mounted bathroom light: a 400mm fitting for a large bathroom, which does the work of four downlights with one hole in the ceiling.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 400mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 2800 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 2.6 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023157268862,"sku":"BBM-CEI-024-27","price":144.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023157301630,"sku":"BBM-CEI-024-30","price":144.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023157334398,"sku":"BBM-CEI-024-40","price":144.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Large_IP65_Ceiling_Light_at_400mm_in_Matt_Black.jpg?v=1789239864"},{"product_id":"ip44-ceiling-light-with-tunable-colour-in-matt-white","title":"IP44 Ceiling Light with Tunable Colour in Matt White","description":"\u003cp\u003eA surface mounted bathroom light: 2700K to 5000K on the wall switch, changed by flicking the switch twice, which needs no extra wiring at all.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1500 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.5 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023157367166,"sku":"BBM-CEI-025-27","price":99.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023157399934,"sku":"BBM-CEI-025-30","price":99.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023157432702,"sku":"BBM-CEI-025-40","price":99.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Ceiling_Light_with_Tunable_Colour_in_Matt_White.jpg?v=1789239812"},{"product_id":"ip44-ceiling-light-with-tunable-colour-in-brushed-chrome","title":"IP44 Ceiling Light with Tunable Colour in Brushed Chrome","description":"\u003cp\u003eA surface mounted bathroom light: 2700K to 5000K on the wall switch, changed by flicking the switch twice, which needs no extra wiring at all.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1500 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.5 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023157465470,"sku":"BBM-CEI-026-27","price":109.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023157498238,"sku":"BBM-CEI-026-30","price":109.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023157531006,"sku":"BBM-CEI-026-40","price":109.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Ceiling_Light_with_Tunable_Colour_in_Brushed_Chrome.jpg?v=1789239807"},{"product_id":"ip44-ceiling-light-with-tunable-colour-in-matt-black","title":"IP44 Ceiling Light with Tunable Colour in Matt Black","description":"\u003cp\u003eA surface mounted bathroom light: 2700K to 5000K on the wall switch, changed by flicking the switch twice, which needs no extra wiring at all.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1500 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.5 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023157563774,"sku":"BBM-CEI-027-27","price":114.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023157596542,"sku":"BBM-CEI-027-30","price":114.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023157629310,"sku":"BBM-CEI-027-40","price":114.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Ceiling_Light_with_Tunable_Colour_in_Matt_Black.jpg?v=1789239800"},{"product_id":"marine-grade-ip65-ceiling-light-in-matt-white","title":"Marine Grade IP65 Ceiling Light in Matt White","description":"\u003cp\u003eA surface mounted bathroom light: 316 stainless for a wet room or a coastal house, salt spray tested to 1000 hours.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1600 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 2.2 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023157662078,"sku":"BBM-CEI-028-27","price":159.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023157694846,"sku":"BBM-CEI-028-30","price":159.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023157727614,"sku":"BBM-CEI-028-40","price":159.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Marine_Grade_IP65_Ceiling_Light_in_Matt_White.jpg?v=1789239864"},{"product_id":"marine-grade-ip65-ceiling-light-in-brushed-chrome","title":"Marine Grade IP65 Ceiling Light in Brushed Chrome","description":"\u003cp\u003eA surface mounted bathroom light: 316 stainless for a wet room or a coastal house, salt spray tested to 1000 hours.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zones 1 and 2. Zone 1 is directly above the bath or the shower tray up to 2.25 metres from the floor, and this fitting is rated for it\u003c\/li\u003e\n\u003cli\u003eIP rating: IP65. Dust tight, and protected against low pressure water jets from any direction. This is the rating for zone 1, which is directly above a bath or in a shower\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1600 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 2.2 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023157760382,"sku":"BBM-CEI-029-27","price":174.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023157793150,"sku":"BBM-CEI-029-30","price":174.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023157825918,"sku":"BBM-CEI-029-40","price":174.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/Marine_Grade_IP65_Ceiling_Light_in_Brushed_Chrome.jpg?v=1789239865"},{"product_id":"ip44-ceiling-light-with-a-night-light-mode-in-matt-white","title":"IP44 Ceiling Light with a Night Light Mode in Matt White","description":"\u003cp\u003eA surface mounted bathroom light: a 1 lux amber mode on a second switch, so nobody has to turn on 1450 lumens at three in the morning.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1450 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.6 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a powder coated matt white that disappears into a ceiling, and the cheapest honest finish we stock\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023157956990,"sku":"BBM-CEI-031-27","price":109.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023157989758,"sku":"BBM-CEI-031-30","price":109.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023158022526,"sku":"BBM-CEI-031-40","price":109.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Ceiling_Light_with_a_Night_Light_Mode_in_Matt_White.jpg?v=1789239811"},{"product_id":"ip44-ceiling-light-with-a-night-light-mode-in-brushed-chrome","title":"IP44 Ceiling Light with a Night Light Mode in Brushed Chrome","description":"\u003cp\u003eA surface mounted bathroom light: a 1 lux amber mode on a second switch, so nobody has to turn on 1450 lumens at three in the morning.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1450 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.6 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: the same triple plate with a directional brush, which hides limescale spotting far better than polished does and is the sensible choice in a hard water area\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023158055294,"sku":"BBM-CEI-032-27","price":119.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023158088062,"sku":"BBM-CEI-032-30","price":119.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023158120830,"sku":"BBM-CEI-032-40","price":119.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Ceiling_Light_with_a_Night_Light_Mode_in_Brushed_Chrome.jpg?v=1789239808"},{"product_id":"ip44-ceiling-light-with-a-night-light-mode-in-matt-black","title":"IP44 Ceiling Light with a Night Light Mode in Matt Black","description":"\u003cp\u003eA surface mounted bathroom light: a 1 lux amber mode on a second switch, so nobody has to turn on 1450 lumens at three in the morning.\u003c\/p\u003e\u003cp\u003eBathroom lighting is the one part of a house where getting it wrong is a safety matter rather than a taste matter, and it is sold almost entirely on photographs. Every listing here states the zone the fitting may be installed in, the IP rating with both digits explained, the colour rendering index, the lumen output and the efficacy in lumens per circuit watt. If a fitting is not suitable above a bath we say so on the page you are buying it from. If a mirror is backlit and will not light your face, we say that too.\u003c\/p\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eZone: zone 2 and outside the zones. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a washbasin tap. It is not rated for zone 1, which means not directly over the bath\u003c\/li\u003e\n\u003cli\u003eIP rating: IP44. The first digit, 4, means protected against solid objects over 1mm. The second digit, 4, means protected against splashing water from any direction. It is the minimum for zone 2 and it is not enough for zone 1\u003c\/li\u003e\n\u003cli\u003eDimensions: 300mm diameter by 60mm deep\u003c\/li\u003e\n\u003cli\u003eLight output: 1450 lumens at 88 lumens per circuit watt. Efficacy is quoted in lumens per circuit watt, which counts the driver losses, rather than lumens per chip watt, which does not. Part L of the Building Regulations asks for 75 lumens per circuit watt on new work and a great many fittings sold as compliant are quoted the other way.\u003c\/li\u003e\n\u003cli\u003eColour temperature: chosen above\u003c\/li\u003e\n\u003cli\u003eColour rendering: CRI 90, with R9 above 50, which is a good deal better than the eighties that this category usually offers and is enough for everything except colour matching makeup\u003c\/li\u003e\n\u003cli\u003eDimming: mains dimmable, trailing edge\u003c\/li\u003e\n\u003cli\u003eElectrical: Class 2, double insulated, with an integral constant current driver. No earth required and nothing separate to find a home for above the ceiling\u003c\/li\u003e\n\u003cli\u003eFire rating: not applicable to a wall or surface mounted fitting\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 60598 for luminaires, BS EN 62471 photobiological safety at the exempt group, BS EN 55015 for electromagnetic emissions, UKCA and CE marked\u003c\/li\u003e\n\u003cli\u003eWeight: approximately 1.6 kilograms\u003c\/li\u003e\n\u003cli\u003eGuarantee: five years on the fitting and the LED module, two years on the driver\u003c\/li\u003e\n\u003cli\u003eFinish: a fine texture matt black powder coat over a chromated primer, because black paint straight onto aluminium in a bathroom lifts at the edges within two years\u003c\/li\u003e\n\u003cli\u003eMounting: surface, onto a ceiling rose position or a joist, with a gasketed base plate\u003c\/li\u003e\n\u003cli\u003eDiffuser: opal polycarbonate, UV stable, which does not yellow the way acrylic does over a decade\u003c\/li\u003e\n\u003cli\u003eSensor: none fitted\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat arrives\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ethe fitting\u003c\/li\u003e\n\u003cli\u003ethe gasketed base plate and gasket\u003c\/li\u003e\n\u003cli\u003efixings for a joist and for plasterboard\u003c\/li\u003e\n\u003cli\u003einstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eA registered electrician, twenty minutes. Electrical work in a room containing a bath or a shower is notifiable under Part P of the Building Regulations in England and Wales. That means it has to be done by a registered electrician or signed off by building control. Replacing a like for like fitting on an existing circuit is not notifiable. Adding a new circuit, a new socket or a new spur is. The base plate gasket needs a flat clean ceiling under it, so a textured ceiling wants skimming flat under the fitting or the seal does nothing.\u003c\/p\u003e\u003ch3\u003eChoosing between this and the alternatives\u003c\/h3\u003e\u003cp\u003eA single flush fitting is the right answer for a great many bathrooms and the trade will always try to sell six downlights instead. One 1450 lumen fitting in the middle of a four square metre bathroom, plus a proper light at the mirror, is better lit than six downlights and costs a fifth as much to install. The case for downlights is a large room, a high ceiling, or a design that wants no visible fitting at all. The zones come from BS 7671, the IET Wiring Regulations. Zone 0 is inside the bath or shower tray. Zone 1 is above it to 2.25 metres. Zone 2 is the 600mm band beyond zone 1 and the 600mm radius around a basin tap. Outside those, the regulations impose no IP requirement, though a bathroom is still a bathroom and steam still rises. Every product page here states which zones the fitting is rated for.\u003c\/p\u003e","brand":"Bathe and Beam","offers":[{"title":"2700K warm white","offer_id":58023158153598,"sku":"BBM-CEI-033-27","price":124.95,"currency_code":"GBP","in_stock":true},{"title":"3000K warm white","offer_id":58023158186366,"sku":"BBM-CEI-033-30","price":124.95,"currency_code":"GBP","in_stock":true},{"title":"4000K neutral white","offer_id":58023158219134,"sku":"BBM-CEI-033-40","price":124.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/1527\/9230\/files\/IP44_Ceiling_Light_with_a_Night_Light_Mode_in_Matt_Black.jpg?v=1789239809"}],"url":"https:\/\/batheandbeam.com\/collections\/ceiling-lights.oembed?page=2","provider":"Bathe \u0026 Beam","version":"1.0","type":"link"}